+printf("\t\t\tProblem Number 8.14\n\n\n");
+// Chapter 8 : Vapor Power Cycles
+// Problem 8.14 (page no. 426)
+// Solution
+
+//From problem 8.11,
+//Leaving turbine:
+h5=1168; //Btu/lbm at 50 psia
+//For the rankine cycle,the Mollier chart gives
+h4=1505; //Enthalpy //Unit:Btu/lbm
+h6=922; //Enthalpy //Unit:Btu/lbm //h6=h5;
+//and at the condenser,
+h1=69.74; //enthalpy //Unit:Btu/lbm
+//Leaving condenser:
+h7=69.74; //Btu/lbm at 1 psia // is equal to h8 if pump work is neglected
+//Leaving heater:
+h2=250.24; //Btu/lbm at 50 psia //is equal to h1 if pump work is neglected(saturated liquid)
+//A Heat balance around the heater gives
+//W*h5 + (1-W)*h7 = 1*h1
+W=((1*h2)-h7)/(h5-h7); //Unit:lbm
+liquidleaving=(W*h2)+(1-W)*h1; //Btu/lbm //liquid leaving the heatexchange
+
+//Using these data,,
+heatin=h4-liquidleaving; //Btu/lbm //heat in the boiler
+printf("Heat in at boiler is %f Btu/lbm\n",heatin);
+workout=((1-W)*(h4-h6))+(W*(h4-h5)); //Btu/lbm //The work out of turbine
+printf("The work out of turbine is %f Btu/lbm\n",workout);
+n=workout/heatin; //efficiency //The conventional thermal efficiency
+printf("The conventional thermal efficiency is %f percentage\n",n*100);
+//If at this time we have define the efficiency of energy utilization to be the ratio of the work out plus the useful heat out divided by the heat input to the cycle, nenergyutilization=((w+qoutuseful)/qin)*100
+qout=W*(h5-h2); //heat out //Btu/lbm
+n=(workout+qout)/heatin; //efficiency of energy utilization
+printf("Efficiency of energy utilization is %f percentage\n",n*100);
+//Comparing with 8.11, we see that conventional thermal efficiency is decreased and efficiency of energy utilization is increased