+clc
+clear
+//Input data
+Wf=10;//Coal rate in t/h
+C=78;//The mass of carbon present in the coal according to coal analysis on mass basis in %
+H=3;//The mass of hydrogen present in the coal according to coal analysis on mass basis in %
+O=3;//The mass of oxygen present in the coal according to coal analysis on mass basis in %
+S=1;//The mass of sulphur present in the coal according to coal analysis on mass basis in %
+M=7;//The mass of moisture present in the coal according to coal analysis on mass basis in %
+A=8;//The mass of ash present in the coal according to coal analysis on mass basis in %
+E=0.3;//Excess air in percentage
+p=180;//Plenum chamber pressure in mm water gauge
+nm=0.6;//Mechanical efficiency of the fan
+ta=30;//Room temperature in degree centigrade
+R=0.287;//Real gas constant
+P=101.325;//Atmospheric pressure in kPa
+g=9.812;//gravitational force constant m/s^2
+
+//Calculations
+Wth=(11.5*(C/100))+(34.5*[(H/100)-(O/(8*100))])+(4.3*(S/100));//Theoretical air required per kg fuel in kg air/kg fuel
+WA=Wth*(1+0.3);//Actual air required per kg fuel in kg air/kg fuel
+Va=(R*(273+ta))/P;//Volume flow rate of air in m^3/kg
+FD=((WA*Wf*1000*Va*p*g)/(3600*nm))/1000;//FD fan motor capacity in kW
+
+//Output
+printf('The required motor capacity needed for the FD fan is %3.2f kW ',FD)