diff --git a/1808/CH6/EX6.14/Chapter6_Exampl14.sce b/1808/CH6/EX6.14/Chapter6_Exampl14.sce new file mode 100644 index 000000000..9635931a7 --- /dev/null +++ b/1808/CH6/EX6.14/Chapter6_Exampl14.sce @@ -0,0 +1,38 @@ +clc
+clear
+//INPUT DATA
+hf1=100.4;//enthalpy in kJ/kg
+hf2=-54.56;//enthalpy in kJ/kg
+hg1=1319.22;//enthalpy in kJ/kg
+hg2=1304.99;//enthalpy in kJ/kg
+sf1=0.3473;//entropy in kJ/kgK
+sf2=-0.2134;//entropy in kJ/kgK
+sg1=4.4852;//entropy in kJ/kgK
+sg2=5.0585;//entropy in kJ/kgK
+t1=20;//temperature in Degree C
+t2=-15;//temperature in Degree C
+mi=30;//mass of ice
+hfgi=335;//enthalpy in kJ/kg
+cpw=4.1868;//specific pressure of water in kJ/kg K
+
+//CALCULATIONS
+x1=((sg1-sf2)/(sg2-sf2));//fraction
+h1=hf2+x1*(hg2-hf2);//enthalpy in kJ/kg
+copt=((h1-hf1)/(hg1-h1));//COP of the system
+copa=copt*0.6;//actual cop
+Qa=mi*10^3*(cpw*t1+hfgi)/(24*3600);//heat removed from water in kJ/s
+w=Qa/copa;//Power required to drive compressor in kW
+
+//OUTPUT
+printf('power required to drive the compresor i %3.2f kW',w)
+
+
+
+
+
+
+
+
+
+
+
|