diff --git a/1775/CH6/EX6.12/Chapter6_Example12.sce b/1775/CH6/EX6.12/Chapter6_Example12.sce new file mode 100755 index 000000000..077290251 --- /dev/null +++ b/1775/CH6/EX6.12/Chapter6_Example12.sce @@ -0,0 +1,31 @@ +//Chapter-6, Illustration 12, Page 318
+//Title: Refrigeration cycles
+//=============================================================================
+clc
+clear
+
+//INPUT DATA
+P1=1;//Pressure at point 1 in bar
+T1=268;//Temperature at point 1 in K
+P2=5;//Pressure at point 2 in bar
+T3=288;//Temperature at point 3 in K
+n=1.3;//Adiabatic gas constant
+Cp=1.005;//Specific heat at constant pressure in kJ/kg-K
+
+//CALCULATIONS
+x=(n-1)/n;//Ratio
+T2=((P2/P1)^x)*T1;//Temperature at point 2 in K
+T4=((P1/P2)^x)*T3;//Temperature at point 4 in K
+W=Cp*(T3-T4);//Work developed per kg of air in kJ/kg
+Re=Cp*(T1-T4);//Refrigerating effect per kg of air in kJ/kg
+Wnet=Cp*((T2-T1)-(T3-T4));//Net work output in kJ/kg
+COP=Re/Wnet;//Co-efficient of performance
+
+//OUTPUT
+mprintf('Work developed per kg of air is %3.3f kJ/kg \n Refrigerating effect per kg of air is %3.3f kJ/kg \n COP of the cycle is %3.2f',W,Re,COP)
+
+
+
+
+
+//==============================END OF PROGRAM=================================
|