summaryrefslogtreecommitdiff
path: root/174/CH4/EX4.7/example4_7.txt
diff options
context:
space:
mode:
Diffstat (limited to '174/CH4/EX4.7/example4_7.txt')
-rwxr-xr-x174/CH4/EX4.7/example4_7.txt10
1 files changed, 10 insertions, 0 deletions
diff --git a/174/CH4/EX4.7/example4_7.txt b/174/CH4/EX4.7/example4_7.txt
new file mode 100755
index 000000000..3db1020cb
--- /dev/null
+++ b/174/CH4/EX4.7/example4_7.txt
@@ -0,0 +1,10 @@
+(a) The value of R_1 and R_2 isThe value of zero-adjust resistor R2 =100.0 ohm
+The value of current-limiting resistor R1 =1966.7 ohm
+
+(b) The maximum value of R2 to compensate the drop in battery voltage = 143 ohm
+The true value of the half-scale mark on the meter is = 2003.713 ohm
+
+(c) The percentage error = -0.185%
+
+ The negative sign indicates that the meter reading is low
+