diff options
Diffstat (limited to '1445/CH3/EX3.8')
-rw-r--r-- | 1445/CH3/EX3.8/ch3_ex_8.sce | 34 |
1 files changed, 34 insertions, 0 deletions
diff --git a/1445/CH3/EX3.8/ch3_ex_8.sce b/1445/CH3/EX3.8/ch3_ex_8.sce new file mode 100644 index 000000000..a060c12ad --- /dev/null +++ b/1445/CH3/EX3.8/ch3_ex_8.sce @@ -0,0 +1,34 @@ +//CHAPTER 3- THREE-PHASE A.C. CIRCUITS +//Example 8 + +disp("CHAPTER 3"); +disp("EXAMPLE 8"); + +//VARIABLE INITIALIZATION +v_ph=230; //in Volts and in polar form +z=8+(%i*6); //in Ohms and in rectanglar form + +//SOLUTION +//converting z from rectangular form to polar form +z_mag=sqrt(real(z)^2+imag(z)^2); +phi=atan(imag(z)/real(z)); //atan() gives output in radians + +I_ph=v_ph/z_mag; +I_l=sqrt(3)*I_ph; +disp(sprintf("The line current is %f A",I_l)); + +pow_fact=cos(phi); +disp(sprintf("The power factor is %f",pow_fact)); + +p=sqrt(3)*v_ph*I_l*pow_fact; //phase volt=line volt in delta connection(v_l=v_ph) +disp(sprintf("The power is %f W",p)); + +var=sqrt(3)*v_ph*I_l*sin(phi); +var=var/1000; //from VAR to kVAR +disp(sprintf("The reactive power is %f kVAR",var)); + +va=sqrt(3)*v_ph*I_l; +va=va/1000; //from VA to kVA +disp(sprintf("The total volt amperes is %f kVA",va)); + +//END |