+//CHAPTER 3- THREE-PHASE A.C. CIRCUITS
+//Example 3
+
+disp("CHAPTER 3");
+disp("EXAMPLE 3");
+
+//VARIABLE INITIALIZATION
+r_ph=30; //in Ohms
+l=0.07; //inductance in Henry
+v_l=400; //in Volts
+v_ph=400; //since in delta connection line voltage=phase voltage
+f=50; //in Hertz
+
+//SOLUTION
+
+//solution (a)
+x_ph=2*(%pi)*f*l; //inductive reactance
+z_ph=sqrt((r_ph^2)+(x_ph^2));
+I_ph=v_ph/z_ph;
+disp(sprintf("(a) The phase current is %f A",I_ph));
+
+//solution (b)
+I_l=sqrt(3)*I_ph;
+disp(sprintf("(b) The line current is %f A",I_l));
+
+//solution (c)
+pow_fact=r_ph/z_ph;
+disp(sprintf("(c) The power factor is %f (lagging)",pow_fact));
+
+//solution (d)
+p=sqrt(3)*v_l*I_l*pow_fact;
+disp(sprintf("(d) The power absorbed is %f W",p));
+
+//Answer is different due to precision of floating point numbers
+
+//END