+// Example 4.2
+// Matrix Node Analysis with two Unknowns
+// From figure 4.6
+G_11= 1/6+1/15+1/12+1/60; // Sum of conductance connected to node 1
+G_22=1/5+1/12+1/60;// Sum of conductance connected to node 2
+G_12=1/12+1/60;
+G_21=G_12; //Equivalent conductance connecting node 1 & 2
+// Conductance matrix is given by
+G=[G_11,-G_12;-G_21,G_22];
+i_s11=30/6+1;// Net Equivalent source current into node 1
+i_s21=50/5-1;// Net Equivalent source current into node 2
+i_s=[i_s11;i_s21]; // Current Vector
+// Using Matrix node Equation G*v=i
+v=G\i_s;
+v_1=v(1,1);
+v_2=v(2,1);
+v_12=v_1-v_2; // Voltage across current source
+i_a=(30-v_1)/6;// Current through 30 source
+i_b=(50-v_2)/5; // Current through 50V source
+p_50= 50*i_b;// Power supplied by 50V source
+p_30=30*i_a;// Power supplied by 30V source
+p_1=v_12*1;// Power supplied by 1A current source
+disp(p_50,"Power supplied by 50V source(in Watt)=")
+disp(p_30,"Power supplied by 30V source(in Watt)=")
+disp(p_1,"Power supplied by 1A source(in Watt)=")