summaryrefslogtreecommitdiff
path: root/1092/CH14/EX14.37/Example14_37.sce
diff options
context:
space:
mode:
Diffstat (limited to '1092/CH14/EX14.37/Example14_37.sce')
-rwxr-xr-x1092/CH14/EX14.37/Example14_37.sce56
1 files changed, 56 insertions, 0 deletions
diff --git a/1092/CH14/EX14.37/Example14_37.sce b/1092/CH14/EX14.37/Example14_37.sce
new file mode 100755
index 000000000..177bbc969
--- /dev/null
+++ b/1092/CH14/EX14.37/Example14_37.sce
@@ -0,0 +1,56 @@
+// Electric Machinery and Transformers
+// Irving L kosow
+// Prentice Hall of India
+// 2nd editiom
+
+// Chapter 14: TRANSFORMERS
+// Example 14-37
+
+clear; clc; close; // Clear the work space and console.
+
+// Given data
+// Δ-Δ transformers in Ex.35
+kVA_1 = 20 ; // kVA rating of transformer 1
+kVA_2 = 20 ; // kVA rating of transformer 2
+kVA_3 = 20 ; // kVA rating of transformer 3
+
+V_1 = 2300 ; // Primary voltage in volt
+V_2 = 230 ; // Secondary voltage in volt
+
+kVA = 40 ; // kVA supplied by the bank
+PF = 0.7 ; // lagging power factor at which bank supplies kVA
+
+// one defective transformer is removed
+
+// Calculations
+// case a
+kVA_transformer = kVA / sqrt(3); // kVA load carried by each transformer
+
+// case b
+percent_ratedload_Tr = kVA_transformer / kVA_1 * 100 ; // percent load carried by each transformer
+
+// case c
+kVA_V_V = sqrt(3)*kVA_1 ; // Total kVA rating of the transformer bank in V-V
+
+// case d
+ratio_banks = kVA_V_V / (kVA_1 + kVA_2 + kVA_3) * 100; // ratio of V-V bank to Δ-Δ bank Tr ratings
+
+// case e
+kVA_Tr = kVA / 3 ;
+percent_increase_load = kVA_transformer / kVA_Tr * 100 ; // percent increase in load on each transformer when one Tr is removed
+
+
+// Display the results
+disp("Example 14-37 Solution : ");
+
+printf(" \n a: kVA load carried by each transformer = %.1f kVA/transformer\n",kVA_transformer);
+
+printf(" \n b: percent rated load carried by each transformer = %.1f percent \n",percent_ratedload_Tr);
+
+printf(" \n c: Total kVA rating of the transformer bank in V-V = %.2f kVA \n",kVA_V_V);
+
+printf(" \n d: ratio of V-V bank to Δ-Δ bank Tr ratings = %.1f percent \n",ratio_banks);
+
+printf(" \n e: kVA load carried by each transformer(V-V) = %.2f kVA/transformer\n",kVA_Tr);
+printf(" \n percent increase in load on each transformer when one Tr is removed :");
+printf(" \n = %.1f percent",percent_increase_load);