+// Electric Machinery and Transformers
+// Irving L kosow
+// Prentice Hall of India
+// 2nd editiom
+
+// Chapter 14: TRANSFORMERS
+// Example 14-35
+
+clear; clc; close; // Clear the work space and console.
+
+// Given data
+I_L = 100 ; // Load current in A
+cos_theta = 0.7 ; // power factor lagging
+
+// Δ-Δ distribution transformer
+S = 60 ; // kVA rating of transformer
+V_1 = 2300 ; // primary voltage in volt
+V_2 = 230 ; // secondary voltage in volt
+
+// Calculations
+// case a
+V_L = 230 ; // voltage across load in volt
+P_T = (sqrt(3)*V_L*I_L*cos_theta)/1000 ; // power consumed by the plant in kW
+kVA_T = P_T/cos_theta ; // apparent power in kVA
+
+// case b
+kVA = S ; // kVA rating of transformer
+V_p = V_2 ; // phase voltage in volt
+I_P2_rated = (kVA*1000)/(3*V_p); // Rated secondary phase current in A
+I_L2_rated = sqrt(3)*I_P2_rated ; // Rated secondary line current in A
+
+// case c
+//percent load on each transformer = (load current per line) / (rated current per line)
+percent_load = I_L / I_L2_rated * 100 ;
+
+// case d
+// subscript d for V_L indicates case d ,V_L
+V_L_d = 2300 ;
+I_P1 = (kVA_T*1000)/(sqrt(3)*V_L_d); // primary phase current in A
+I_L1 = sqrt(3)*I_P1 ; // primary line current in A
+
+// case e
+kVA_transformer = kVA / 3 ; // kVA rating of each transformer
+
+// Display the results
+disp("Example 14-35 Solution : ");
+
+printf(" \n a: power consumed by the plant :\n P_T = %.1f kW \n ",P_T);
+printf(" \n apparent power :\n kVA_T = %.1f kVA \n",kVA_T);
+
+printf(" \n b: Rated secondary phase current :\n I_P2(rated) = %f A ≃ %.f A \n",I_P2_rated,I_P2_rated);
+printf(" \n Rated secondary line current :\n I_L2(rated) = %f A ≃ %.1f A \n",I_L2_rated,I_L2_rated);
+
+printf(" \n c: percent load on each transformer = %.1f percent \n ",percent_load);
+
+printf(" \n d: primary phase current :\n I_P1 = %.f A \n",I_P1);
+printf(" \n primary line current :\n I_L1 = %f A ≃ %.1f A \n",I_L1,I_L1);
+printf(" \n The primary line current drawn by a Δ-Δ bank is √3 times the ");
+printf(" \n line current drawn by a Y-Δ bank.\n");
+
+printf(" \n e: kVA rating of each transformer = %d kVA",kVA_transformer);