diff --git a/1092/CH13/EX13.5/Example13_5.sce b/1092/CH13/EX13.5/Example13_5.sce new file mode 100755 index 000000000..913e7ed13 --- /dev/null +++ b/1092/CH13/EX13.5/Example13_5.sce @@ -0,0 +1,45 @@ +// Electric Machinery and Transformers
+// Irving L kosow
+// Prentice Hall of India
+// 2nd editiom
+
+// Chapter 13: RATINGS,SELECTION,AND MAINTENANCE OF ELECTRIC MACHINERY
+// Example 13-5
+
+clear; clc; close; // Clear the work space and console.
+
+// Given data
+P_o = 50 ; // Power rating of the WRIM in hp
+// Class F insulation
+T_hottest = 160 ; // Hottest-spot winding temperature recorded by the embedded
+// hot-spot detectors in degree celsius
+T_ambient = 40 ; // Standard ambient temperature recorded by the embedded
+// hot-spot detectors in degree celsius
+P_f_a = 40 ; // Power rating of load a in hp
+P_f_b = 55 ; // Power rating of load a in hp
+
+// Calculations
+// case a
+delta_T_o = T_hottest - T_ambient ; // Temperature rise for the insulation type
+// used in degree celsius
+
+// subscript a in delta_T_f ,P_f_a and T_f indicates case a
+delta_T_f_a = (P_f_a/P_o)*delta_T_o ; // final temperature rise in degree celsius
+T_f_a = delta_T_f_a + T_ambient ; // Approximate final hot-spot temperature in degree celsius
+
+// case b
+// subscript b in delta_T_f ,P_f and T_f indicates case b
+delta_T_f_b = (P_f_b/P_o)*delta_T_o ; // final temperature rise in degree celsius
+T_f_b = delta_T_f_b + T_ambient ; // Approximate final hot-spot temperature in degree celsius
+
+// Display the results
+disp("Example 13-5 Solution : ");
+printf(" \n a: ΔT_o = %d degree celsius ",delta_T_o);
+printf(" \n ΔT_f = %d degree celsius ",delta_T_f_a);
+printf(" \n T_f = %d degree celsius \n",T_f_a);
+
+printf(" \n b: ΔT_f = %d degree celsius ",delta_T_f_b);
+printf(" \n T_f = %d degree celsius \n",T_f_b);
+printf(" \n Yes,motor life is reduced at the 110 percent motor load because");
+printf(" \n the allowable maximum hot-spot motor temperature for Class F");
+printf(" \n insulation is 155 degree celsius.");
|