diff --git a/1092/CH12/EX12.1/Example12_1.sce b/1092/CH12/EX12.1/Example12_1.sce new file mode 100755 index 000000000..4d58df864 --- /dev/null +++ b/1092/CH12/EX12.1/Example12_1.sce @@ -0,0 +1,50 @@ +// Electric Machinery and Transformers
+// Irving L kosow
+// Prentice Hall of India
+// 2nd editiom
+
+// Chapter 12: POWER,ENERGY,AND EFFICIENCY RELATIONS OF DC AND AC DYNAMOS
+// Example 12-1
+
+clear; clc; close; // Clear the work space and console.
+
+// Given data
+P = 10000 ; // Power rating of the shunt generator in W
+V = 230 ;// Voltage rating of the shunt generator in volt
+S = 1750 ; // Speed in rpm of the shunt generator
+// Shunt generator was made to run as a motor
+V_a = 245 ; // Voltage across armature in volt
+I_a = 2 ; // Armature current in A
+R_f = 230 ; // Field resistance in ohm
+R_a = 0.2 ; // Armature resistance
+
+// Calculations
+// case a
+Rotational_losses = (V_a * I_a) - (I_a^2 * R_a); // Rotational losses in W at full load
+
+// case b
+V_t = V ;
+// At rated load
+I_L = P / V_t ; // Line current in A
+I_f = V / R_f ; // Field current in A
+Ia = I_f + I_L ; // Armature current in A
+
+armature_loss = (Ia^2 * R_a); // Full-load armature loss in W
+V_f = V ; // Field voltage in volt
+field_loss = V_f * I_f; // Full-load field loss in W
+
+// case c
+//
+eta = P / ( P + Rotational_losses + (armature_loss+field_loss) ) * 100 ;
+
+// Display the results
+disp("Example 12-1 Solution : ");
+
+printf(" \n a: Rotational losses at full load = %.1f W \n",Rotational_losses);
+
+printf(" \n b: At the rated load,\n I_L = %.1f A\n I_a = %.1f A\n",I_L,Ia);
+printf(" \n Full-load armature loss :\n (I_a^2)*R_a = %.f W \n",armature_loss);
+printf(" \n Full-load field loss :\n V_f*I_f = %.f W \n",field_loss);
+
+printf(" \n c: Efficiency of the generator at rated load(full-load in this Ex.) : ");
+printf(" \n η = %.1f percent ",eta);
|