diff options
author | priyanka | 2015-06-24 15:03:17 +0530 |
---|---|---|
committer | priyanka | 2015-06-24 15:03:17 +0530 |
commit | b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b (patch) | |
tree | ab291cffc65280e58ac82470ba63fbcca7805165 /83/CH4/EX4.1 | |
download | Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.gz Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.bz2 Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.zip |
initial commit / add all books
Diffstat (limited to '83/CH4/EX4.1')
-rwxr-xr-x | 83/CH4/EX4.1/example_4_1.sce | 43 | ||||
-rwxr-xr-x | 83/CH4/EX4.1/result_example_4_1.txt | 18 |
2 files changed, 61 insertions, 0 deletions
diff --git a/83/CH4/EX4.1/example_4_1.sce b/83/CH4/EX4.1/example_4_1.sce new file mode 100755 index 000000000..bc919b4a3 --- /dev/null +++ b/83/CH4/EX4.1/example_4_1.sce @@ -0,0 +1,43 @@ +//Chapter 4 +//Example 4.1 +//page 103 +// to draw the per unit reactance diagram +clear;clc; +mvab=30; kvb=33; //MVA base and KVA base are selected + +gen1_mva=30; gen1_kv=10.5; gen1_x=1.6; //Generator No.1 details +gen2_mva=15; gen2_kv=6.6; gen2_x=1.2; //Generator No.2 details +gen3_mva=25; gen3_kv=6.6; gen3_x=0.56; //Generator No.3 details + +t1_mva=15; t1_hv=33; t1_lv=11; t1_x=15.2; //Transformer T1 details +t2_mva=15; t2_hv=33; t2_lv=6.2; t2_x=16; //Transformer T1 details + +tl_x=20.5; //Transmission line recatance + +//Loads are neglected as said in the problem + +tl_pu=(tl_x*mvab)/kvb^2; +t1_pu=(t1_x*mvab)/kvb^2; +t2_pu=(t2_x*mvab)/kvb^2; +gen1_kv_base=t1_lv; +gen1_pu=(gen1_x*mvab)/gen1_kv_base^2; +gen2_kv_base=t2_lv; +gen2_pu=(gen2_x*mvab)/gen2_kv_base^2; +gen3_pu=(gen3_x*mvab)/gen2_kv_base^2; + +//diplaying the results on console + +printf('Per unit impedance of the components of the given power system are as follows :\n\n'); + +printf('Transmission line: %0.3f \n\n',tl_pu); + +printf('Transformer T1: %0.3f \n\n',t1_pu); + +printf('Transformer T2: %0.3f \n\n',t2_pu); + +printf('Generator 1: %0.3f \n\n',gen1_pu); + +printf('Generator 2: %0.3f \n\n',gen2_pu); + +printf('Generator 3: %0.3f \n\n',gen3_pu); + diff --git a/83/CH4/EX4.1/result_example_4_1.txt b/83/CH4/EX4.1/result_example_4_1.txt new file mode 100755 index 000000000..975ce31a8 --- /dev/null +++ b/83/CH4/EX4.1/result_example_4_1.txt @@ -0,0 +1,18 @@ + +Per unit impedance of the components of the given power system are as follows : + +Transmission line: 0.565 + +Transformer T1: 0.419 + +Transformer T2: 0.441 + +Generator 1: 0.397 + +Generator 2: 0.937 + +Generator 3: 0.437 + + + Execution done. + |