diff --git a/3871/CH1/EX1.9/Ex1_9.sce b/3871/CH1/EX1.9/Ex1_9.sce new file mode 100644 index 000000000..4a430fbad --- /dev/null +++ b/3871/CH1/EX1.9/Ex1_9.sce @@ -0,0 +1,23 @@ +//===========================================================================
+//chapter 1 example 9
+
+
+clc;
+clear all;
+
+//variable declaration
+s = 4000; //instrument sensitivity in kΩ
+R = 10; //range of scale
+R0 = 20; //output resistance in kΩ
+E0 = 7.5; //open circuit voltage
+
+//calculations
+RL =s*R; //instrument resistance in kΩ
+RL1 = RL*10^-3;
+EL = E0/(1+(R0/(RL1))); //measured value of voltage in V
+p = ((EL-E0)/(E0))*100; //percentage error in %
+
+//result
+mprintf("measured value of voltage = %3.2f V",EL);
+mprintf("\npercentage error = %3.2f V percentage low",p);
+
|