summaryrefslogtreecommitdiff
path: root/3554/CH1/EX1.8/Ex1_8.sce
diff options
context:
space:
mode:
authorprashantsinalkar2017-10-10 12:27:19 +0530
committerprashantsinalkar2017-10-10 12:27:19 +0530
commit7f60ea012dd2524dae921a2a35adbf7ef21f2bb6 (patch)
treedbb9e3ddb5fc829e7c5c7e6be99b2c4ba356132c /3554/CH1/EX1.8/Ex1_8.sce
parentb1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b (diff)
downloadScilab-TBC-Uploads-7f60ea012dd2524dae921a2a35adbf7ef21f2bb6.tar.gz
Scilab-TBC-Uploads-7f60ea012dd2524dae921a2a35adbf7ef21f2bb6.tar.bz2
Scilab-TBC-Uploads-7f60ea012dd2524dae921a2a35adbf7ef21f2bb6.zip
initial commit / add all books
Diffstat (limited to '3554/CH1/EX1.8/Ex1_8.sce')
-rw-r--r--3554/CH1/EX1.8/Ex1_8.sce23
1 files changed, 23 insertions, 0 deletions
diff --git a/3554/CH1/EX1.8/Ex1_8.sce b/3554/CH1/EX1.8/Ex1_8.sce
new file mode 100644
index 000000000..9662b2138
--- /dev/null
+++ b/3554/CH1/EX1.8/Ex1_8.sce
@@ -0,0 +1,23 @@
+// Exa 1.8
+
+clc;
+clear all;
+
+// Given data
+
+X= 100; // Range of voltmeter(V)
+x= 70; // Measured value on voltmeter(V)
+Y= 150; // Range of milliammeter
+y= 80; // Measurex d value on milliammeter
+Accu= 0.015; // Accuracy of instruments
+
+// Solution
+
+X_mag= Accu*X; //Magnitude of limiting error for voltmeter
+Y_mag= Accu*Y; // Magnitude of limiting error for milliammeter
+x_mag= X_mag/x; // limiting error at 70V
+y_mag= Y_mag/y; // limiting error at 80mA
+
+disp("Limiting error for the power calculation is the sum of the individual limiting errors involved");
+printf(' Therefore, limiting error = %.3f percentage \n',(x_mag+y_mag)*100);
+// The answer vary due to round off error