+disp("Engineering Thermodynamics by Onkar Singh Chapter 4 Example 8")
+T1=(27+273);//temperature of source in K
+T2=(-8+273);//temperature of sink in K
+Q=7.5;//heat leakage in KJ/min
+disp("here heat to be removed continuously from refrigerated space(Q)in KJ/s")
+Q=Q/60
+disp("for refrigerated,COP shall be Q/W=1/((T1/T2)-1)")
+disp("W=Q*((T1/T2)-1) in KW")
+W=Q*((T1/T2)-1)
+disp("so power required(W)in KW")
+W
|