summaryrefslogtreecommitdiff
path: root/2873/CH10/EX10.11
diff options
context:
space:
mode:
authorpriyanka2015-06-24 15:03:17 +0530
committerpriyanka2015-06-24 15:03:17 +0530
commitb1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b (patch)
treeab291cffc65280e58ac82470ba63fbcca7805165 /2873/CH10/EX10.11
downloadScilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.gz
Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.bz2
Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.zip
initial commit / add all books
Diffstat (limited to '2873/CH10/EX10.11')
-rwxr-xr-x2873/CH10/EX10.11/Ex10_11.jpgbin0 -> 212268 bytes
-rwxr-xr-x2873/CH10/EX10.11/Ex10_11.sce34
2 files changed, 34 insertions, 0 deletions
diff --git a/2873/CH10/EX10.11/Ex10_11.jpg b/2873/CH10/EX10.11/Ex10_11.jpg
new file mode 100755
index 000000000..22c7559da
--- /dev/null
+++ b/2873/CH10/EX10.11/Ex10_11.jpg
Binary files differ
diff --git a/2873/CH10/EX10.11/Ex10_11.sce b/2873/CH10/EX10.11/Ex10_11.sce
new file mode 100755
index 000000000..4c9e9edc2
--- /dev/null
+++ b/2873/CH10/EX10.11/Ex10_11.sce
@@ -0,0 +1,34 @@
+// Display mode
+mode(0);
+// Display warning for floating point exception
+ieee(1);
+clear;
+clc;
+disp("Engineering Thermodynamics by Onkar Singh Chapter 10 Example 11")
+BP=50;//brake power output at full load in KW
+BP1=40.1;//brake power output of 1st cylinder in KW
+BP2=39.5;//brake power output of 2nd cylinder in KW
+BP3=39.1;//brake power output of 3rd cylinder in KW
+BP4=39.6;//brake power output of 4th cylinder in KW
+BP5=39.8;//brake power output of 5th cylinder in KW
+BP6=40;//brake power output of 6th cylinder in KW
+disp("indicated power of 1st cylinder=BP-BP1 in KW")
+BP-BP1
+disp("indicated power of 2nd cylinder=BP-BP2 in KW")
+BP-BP2
+disp("indicated power of 3rd cylinder=BP-BP3 in KW")
+BP-BP3
+disp("indicated power of 4th cylinder=BP-BP4 in KW")
+BP-BP4
+disp("indicated power of 5th cylinder=BP-BP5 in KW")
+BP-BP5
+disp("indicated power of 6th cylinder=BP-BP6 in KW")
+BP-BP6
+disp(" total indicated power(IP)in KW")
+IP=9.9+10.5+10.9+10.4+10.2+10
+disp("mechanical efficiency(n_mech)=BP/IP")
+n_mech=BP/IP
+disp("in percentage")
+n_mech=n_mech*100
+disp("so indicated power=61.9 KW")
+disp("mechanical efficiency=80.77%")