diff --git a/2642/CH8/EX8.2/Ex8_2.sce b/2642/CH8/EX8.2/Ex8_2.sce new file mode 100755 index 000000000..a2c924c20 --- /dev/null +++ b/2642/CH8/EX8.2/Ex8_2.sce @@ -0,0 +1,24 @@ +// FUNDAMENTALS OF ELECTICAL MACHINES
+// M.A.SALAM
+// NAROSA PUBLISHING HOUSE
+// SECOND EDITION
+
+// Chapter 8 : STARTING, CONTROL AND TESTING OF AN INDUCTION MOTOR
+// Example : 8.2
+
+clc;clear; // clears the console and command history
+
+// Given data
+T_ratio = 1/2 // T_st/T_f ratio of starting torque to full load torque
+s_f = 0.03 // full load slip
+I_ratio = 5 // I_sc/I_f ratio pf short circuit current to full load current
+
+// caclulations
+x = (1/I_ratio)*sqrt(T_ratio*(1/s_f)) // percentage of tapping
+
+// display the result
+disp("Example 8.2 solution");
+printf(" \n Percentage of tapping \n x = %.3f \n", x );
+
+
+
|