diff options
author | priyanka | 2015-06-24 15:03:17 +0530 |
---|---|---|
committer | priyanka | 2015-06-24 15:03:17 +0530 |
commit | b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b (patch) | |
tree | ab291cffc65280e58ac82470ba63fbcca7805165 /1445/CH10/EX10.11 | |
download | Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.gz Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.tar.bz2 Scilab-TBC-Uploads-b1f5c3f8d6671b4331cef1dcebdf63b7a43a3a2b.zip |
initial commit / add all books
Diffstat (limited to '1445/CH10/EX10.11')
-rw-r--r-- | 1445/CH10/EX10.11/Ex10_11.sce | 25 |
1 files changed, 25 insertions, 0 deletions
diff --git a/1445/CH10/EX10.11/Ex10_11.sce b/1445/CH10/EX10.11/Ex10_11.sce new file mode 100644 index 000000000..143337fe8 --- /dev/null +++ b/1445/CH10/EX10.11/Ex10_11.sce @@ -0,0 +1,25 @@ +//CHAPTER 10- THREE-PHASE INDUCTION MACHINES +//Example 11 + +disp("CHAPTER 10"); +disp("EXAMPLE 11"); + +//VARIABLE INITIALIZATION +P1=4; //number of poles +s=5/100; //slip +f=60; //frequency of synchronous generator in Hertz + +//SOLUTION + +//solution (a) +N_s=(120*f)/P1; //synchronous speed of generator in rpm with four poles +N_r=N_s*(1-s); //rotor or motor speed in rpm +N_r=round(N_r); //to round off the value +disp(sprintf("(a) The speed of the motor is %d rpm",N_r)); + +//solution (b) +P2=6; // number of poles +N_s=(120*f)/P2; //synchronous speed of generator in rpm with six poles +disp(sprintf("(b) The speed of the generator is %d rpm",N_s)); + +//END |