clc //ex5.12 V_Y=1000; //line to neutral voltage f=60; //frequency L=0.1; //inductance R=50; W=2*%pi*f; //angular frequency Z=complex(R,W*L); //complex impedance phi=atan(imag(Z)/real(Z)); //Balanced wye-wye calculations V_an=complex(1000*cos(0),1000*sin(0)); V_bn=complex(1000*cos(-2*%pi/3),1000*sin(-2*%pi/3)); V_cn=complex(1000*cos(2*%pi/3),1000*sin(2*%pi/3)); I_aA=V_an/Z; I_bB=V_bn/Z; I_cC=V_cn/Z; //line-line phasors V_ab=V_an*sqrt(3)*complex(cos(%pi/6),sin(%pi/6)); V_bc=V_bn*sqrt(3)*complex(cos(%pi/6),sin(%pi/6)); V_ca=V_cn*sqrt(3)*complex(cos(%pi/6),sin(%pi/6)); I_L=abs(I_aA); P=(3/2)*V_Y*I_L*cos(phi); //power Q=(3/2)*V_Y*I_L*sin(phi); //reactive power printf(" All the values in the textbook are approximated hence the values in this code differ from those of Textbook") disp('LINE CURRENTS') disp(I_aA,'IaA=') disp(I_bB,'IbB=') disp(I_cC,'IcC=') disp('LINE-LINE VOLTAGES') disp(V_ab,'Vab=') disp(V_bc,'Vbc=') disp(V_ca,'Vca=') disp(P,'POWER IN WATTS') disp(Q,'REACTIVE POWER IN VARs') disp('the phasor diagram cannot be plotted')