(a)Equivalent rotor current per phase(in A)= 52.083013 - 16.233666i (b)Stator current per phase(in A)= 55.016346 - 40.678111i (c)Power factor= 0.8040793 (d)Rotor input(in watt)= 22321.291 (e)Rotor copper losses(in watts)= 892.85165 (f)Torque(in N-m)= 284.20351 (g)Mechanical power output from rotor(in watts per phase)= 21178.44 (h)Stator input(in watts per phase)= 24207.192 (i)Efficiency (in %)= 87.488211