//(Manufacturing Considerations in Design) Example 3.2 //Refer Fig. 3.26 on page 70 //Basic diameter of housing Dh mm Dh = 20 //Refer tables 3.2 and 3.3b for tolerances of H7-s6 fit //Upper deviation for housing Uh mm Uh = 0.021 //Lower deviation for housing Lh mm Lh = 0.000 //Basic diameter of valve seat(outer diameter) Dv mm Dv = 20 //Upper deviation for valve seat Uv mm Uv = 0.048 //Lower deviation for valve seat Lv mm Lv = 0.035