//(Threaded Joints)Example 7.9 //Refer Fig.7.24 on page 240 //Number of bolts N N = 4 //Load supported by the bracket P (kN) P = 25 //Distance of bolt1 from C l1 (mm) l1 = 50 //Distance of bolt2 from C l2 (mm) l2 = 200 //Eccentricity value l (mm) l = 400 //Permissible tensile stress in the bolt sigmaMax (N/mm2) sigmaMax = 50