-->//(Threaded Joints) Example 7.7 -->//Refer Fig.7.22 on page 238 -->//Number of bolts N -->N = 6 N = 6. -->//Load acting on the bracket P (kN) -->P = 50 P = 50. -->//Height of bolt1 from the base l1 (mm) -->l1 = 300 l1 = 300. -->//Height of bolt2 from the base l2 (mm) -->l2 = 200 l2 = 200. -->//Height of bolt3 from the base l3 (mm) -->l3 = 100 l3 = 100. -->//Eccentricity value l (mm) -->l = 250 l = 250. -->//Maximum permissible tensile stress in bolts sigmaMax (N/mm2) -->sigmaMax = 100 sigmaMax = 100. Area at the core cross-section(A) = 133.928571 mm2