//(Threaded Joints) Example 7.7 //Refer Fig.7.22 on page 238 //Number of bolts N N = 6 //Load acting on the bracket P (kN) P = 50 //Height of bolt1 from the base l1 (mm) l1 = 300 //Height of bolt2 from the base l2 (mm) l2 = 200 //Height of bolt3 from the base l3 (mm) l3 = 100 //Eccentricity value l (mm) l = 250 //Maximum permissible tensile stress in bolts sigmaMax (N/mm2) sigmaMax = 100