//(Threaded Joints) Example 7.15 //Refer Fig.7.30 on page 247 //Vertical force acting on the rigid bracket P (kN) P = 10 //Maximum permissible shear stress in any bolt tauMax (N/mm2) tauMax = 50 //Number of bolts N N = 4 //Eccentricity value when secondary shear is considered e (mm) e = 250 //Distance between two bolts dist (mm) dist = 100 + 100 //Angle made by the secondary shear forces with the vertical theta (degree) theta = 45 //Eccentricity value when bracket tilting is considered et (mm) et = 300 //Distance between bolts 1 and 3 from edge CC l1 (mm) l1 = 50 + 200 //Distance between bolts 2 and 4 from edge CC l2 (mm) l2 = 50