//(Design against Fluctuating Load) Example 5.5 //Refer Fig.5.29 on page 161 //Completely reversed axial load acting on the plate P (kN) P = 50 //Ultimate tensile strength of 45C8 Sut (N/mm2) Sut = 630 //Factor of safety fs fs = 2 //Notch sensitivity factor q q = 0.8 //Dimensions in mm r = 5 d = 50 D = 100 //Reliability (%) reliability = 90 //Operation //Nomenclature: //1 - Ground //2 - Machined or cold drawn //3 - Hot-rolled //4 - Forged op = 2 //From Fig.5.3 Kt = 2.27