//(Design against Fluctuating Load) Example 5.15 //Refer Fig.5.46 on page 172 //Spring wire diameter d (mm) d = 10 //Ultimate tensile strength of 4Cr18Ni10 Sut (N/mm2) Sut = 860 //Yield tensile strength of 4Cr18Ni10 Syt (N/mm2) Syt = 690 //Minimum value of N is Nmin Nmin = (10^3) //Maximum value of N is Nmax Nmax = (10^6) //Maximum force acting at the free end Pmax (N) Pmax = 150 //Minimum force acting at the free end Pmin (N) Pmin = 75 reliability = 50 //Operation //Nomenclature: //1 - Ground //2 - Machined or cold drawn //3 - Hot-rolled //4 - Forged op = 2 //Distance between force and stress concentration point dist (mm) dist = 500