-->//(Design against Fluctuating Load) Example 5.11 -->//Ultimate tensile strength of 50C4 Sut (N/mm2) -->Sut = 660 Sut = 660. -->//Corrected endurance limit Se (N/mm2) -->Se = 280 Se = 280. -->//Minimum value of N is Nmin -->Nmin = (10^3) Nmin = 1000. -->//Maximum value of N is Nmax -->Nmax = (10^6) Nmax = 1000000. -->//The three elements provided -->//Stress in N/mm2 and time in % -->stress = {350 400 500} stress = 350. 400. 500. -->time = {85 12 3} time = 85. 12. 3. Life of component(Nfinal) = 62731.118105 cycles