//(Design against Fluctuating Load) Example 5.1 //Refer Fig.5.13 on page 149 //Tensile force acting on the flat plate P (kN) P = 5 //Ultimate tensile strength of FG200 Sut (N/mm2) Sut = 200 //Factor of safety fs fs = 2.5 //Values of the geometry are as follows (mm) D = 45 w = 30 //Fillet radius r (mm) r = 5 //Hole diameter d (mm) d = 15 //From Fig.5.3 on page 143 for fillet section Kt1 = 1.8 //From Fig.5.2 on page 143 for hole section Kt2 = 2.16