-->//(Design against Static Load) Example 4.16 -->//Refer Fig.4.53 on page 123 -->//Load to be raised F (kN) -->F = 5 F = 5. -->//Length of short arm l1 (mm) -->l1 = 100 l1 = 100. -->//Length of long arm l2 (mm) -->l2 = 450 l2 = 450. -->//Tensile yield strength of 30C8 Syt (N/mm2) -->Syt = 400 Syt = 400. -->//Factor of safety fs -->fs = 5 fs = 5. -->//Permissible bearing pressure at the pin in the lever p (N/mm2) -->p = 10 p = 10. -->//Ratio of width to thickness ratio -->ratio = 3 ratio = 3. -->//Ratio of length to diameter of the fulcrum pin rf -->rf = 1.25 rf = 1.25 Diameter of the fulcrum pin(df) = 20.242469 mm Length of the fulcrum pin(lf) = 25.303086 mm Force to be applied at the long arm end(P) = 1111.111111 mm Thickness of the cross-section of the lever(b) = 16.091490 mm Width of the cross-section of the lever(d) = 48.274469 mm