-->//(Design against Static Load) Example 4.15 -->//Refer Fig.4.50 on page 121 -->//Safety valve blow-off pressure p (MPa) -->p = 1.5 p = 1.5 -->//Effective diameter of the valve opening d (mm) -->de = 50 de = 50. -->//Distance between fulcrum and lever dead weights l1 (mm) -->l1 = 1000 l1 = 1000. -->//Distance between the fulcrum and the pin connecting the valve spindle to the lever l2 (mm) -->l2 = 100 l2 = 100. -->//Tensile yield strength of 30C8 Syt (N/mm2) -->Syt = 400 Syt = 400. -->//Factor of safety fs -->fs = 5 fs = 5. -->//Permissible bearing pressure at the pin in the lever Bp (N/mm2) -->Bp = 25 Bp = 25. -->//Ratio of width to thickness ratio -->ratio = 3 ratio = 3. The diamater of the pin(dp) = 11.000000 mm The length of the pin(lp) = 20.000000 mm The thickness of the lever cross-section(b) = 15.000000 mm The width of the lever cross-sectio(d) = 45.000000 mm The dead weight(P) = 294.524311 mm The lever design is safe