-->//(Design against Static Load) Example 4.12 -->//Refer Fig.4.39 -->//Force acting on the bracket P (kN) -->P = 5 P = 5. -->//Ultimate tensile strength of FG200 material Sut (N/mm2) -->Sut = 200 Sut = 200. -->//Factor of safety fs -->fs = 3.5 fs = 3.5 -->//Angle made by the line of force with the vertical theta (radian) -->theta = (60 * (%pi/180)) theta = 1.0471976 -->//Distance between the point load and the horizontal axis h (mm) -->h = 150 h = 150. -->//Distance between the point load and the rigid support r (mm) -->r = 300 r = 300. -->//Ratio of depth to width of the cross-section ratio -->ratio = 2 ratio = 2. Value of t = 35.000000 mm Area of cross-section = (35.000000 x 70.000000) mm2