//Chapter 7_Operational Amplifier Characteristics //Caption : Slew rate and Fmax //Example7.15: For type 741 Op-Amp following parameter are given.Quiescent collector current Ic=9.5 uA, Cc=30 pF. Peak amplitude of input voltage Vm=15V. //a)Determine the slew rate //b)Determine full power bandwidth Fmax for the slew rate as obtained from part (a). clear; clc; //a)Solution: Ic=9.5*10^-6;// operating collector current in A Cc=30*10^-12;// parasitic capacitance SlewRate=2*Ic/Cc; disp('V/us',SlewRate/10^6,'Slew rate is:') //b)Solution: Vm=15;//amplitude of input voltage in Volt Fmax=SlewRate/(2*%pi*Vm);// full power bandwidth disp('kHz',Fmax/10^3,'full power bandwidth Fmax for the Slew Rate obtained above is:')