clear clc //Example 14.5 HEAD, DISCHARGE, AND POWER OF CENTRIFUGAL PUMP g=9.81; //[ft/s^2] n=400/60 //speed[rps] D=1.98//diameter[m] //From fig.14.10 CQ=0.12; CH=5.2; CP=0.69; H=CH*D^2*n^2/g //head[ft] Q=CQ*n*D^3 //discharge[m^3/s] rho=10^3; //density[Kg/m^3] P=CP*rho*D^5*n^3/10^3 //power[kW] printf("\n At maximum efficiency, the expected values of\n Head = %.1f m\n Discharge = %.2f m^3/s\n Power = %.f kW\n",H,Q,P)