// Calculating the maximum voltage sensitivity of the bridge clc; P=(0.1/0.2)*10^-3; R=1000; eim=2*(P*R)^0.5; dth=0.1; dR=(4.5/100)*dth*R; eom=(dR/(4*R))*eim; Sem=eom/dth; disp(Sem,'maximum voltage sensitivity of the bridge (V)=')