clc h1=3315; //kJ/kg h2=2716; //kJ/kg h3=3165; //kJ/kg h4=2236; //kJ/kg h_f2=697.1;//kJ/kg h_f6=h_f2; h_f4=111.9; //kJ/kg h_f5=h_f4; disp("(i) Amount of steam bled off for feed heating =") m=(h_f2-h_f4)/(h2-h_f4); disp(m) disp("steam bled off is 22.5% of steam generated by the boiler.") disp("(ii) Amount of steam supplied to L.P. turbine =") amt=100-m*100; disp(amt) disp("77.5% of the steam generated by the boiler.") disp("(iii) Heat supplied in the boiler and reheater") Q_boiler=h1-h_f6; disp("Q_boiler=") disp(Q_boiler) disp("kJ/kg") Q_reheater=(1-m)*(h3-h2); disp("Q_reheater=") disp(Q_reheater) disp("kJ/kg") Qs=Q_boiler+Q_reheater; disp("(iv) Cycle efficiency") W=h1-h2 + (1-m)*(h3-h4); n_cycle=W/Qs; disp("n_cycle=") disp(n_cycle) disp("(v) Power developed by the system") ms=50; //kg/s Power=ms*W/1000; //MW disp("Power=") disp(Power) disp("MW")