// Example 10_3 clc;funcprot(0); // Given data T=200;// °C P=1554;// kPa R=0.462;// kJ/kg.K // Calculation v_g=(R*(T+273))/P;// m^3/kg rho=1000;// kg/m^3 v_f=0.001;// m^3/kg dPbydT=(1906-1254)/(210-190);// kN/m^2.K h_fg=(T+273)*(v_g-v_f)*dPbydT;// kJ/kg h_fga=1941;// kJ/kg (From steam tables) error=((h_fg-h_fga)/h_fga)*100;// The percentage error printf("\nThe percent error=%2.1f percentage",error);