//Example 1_8 page no:75 clc; //given voltage = 2200;//in V power = 110;//in kW rpm = 750;// rotation per minute inertia = 62;//in kg.m^2 resistance = 13;//in ohm efficiency = 0.93;//93% converted to decimal fl_load_torque = (power * 1000 * 60)/(2*%pi*rpm); fl_ld_line_current = (power * 1000)/(sqrt(3)*voltage* efficiency); ln_current = 2000/(sqrt(3)*resistance); ele_brk_torque = 4200;//in Nm tot_brk_torque = ele_brk_torque + 1400; omega = (rpm * 2* %pi)/60; Te = 4200;//in Nm K = Te/omega; t = ((60/K)*log(5600/1400)); disp(t,"the time taken is (in s)"); r = ((1.12*5600/(2*%pi*53.5))*(1-exp(-0.893*1.55))+1.7)-((1400/(2*%pi*53.5))*1.95); disp(r,"the number of revolution made before the motor stopped is (no unit)");//it is count it has no unit