// elevation that the diameter pump can be situated above the water surface of suction clc patm=101e3 pv=1666 g=9800 npsh=7.4 z1=((patm-pv)/g)-npsh mprintf('\n Z1= %f m',z1) mprintf('\n the pump must be place at approximately %f m above the suction reservoir of water surface',z1)