// design of termengor power stations // ex 7.7 pgno.178 clc Q=125.4 // flow rate at m3/s H=101 // m N=214.3 // speed in rev/min p=90e6 // power to turbine in wattsr g=9.8 w=(2*N*%pi)/60 mprintf('\n Wt =%f rad/s',w) wt=(w*(sqrt(p/10^3)))/((g*H)^(5/4)) mprintf('\n wt= %f',wt) Ns=(N*sqrt(90*1000))/((H)^(5/4))// specific speed mprintf('\n Ns = %f ',Ns) n0=p/(9800*Q*H) // overall efficiency mprintf('\n Over all efficiency n0= %f percentage',n0*100)