//Caption:Determine the reading of two wattmeters,total power and power factor //Exa:1.7 clc; clear; close; //transforming delta connected source into an equivalent Star-connected source V_s=1351;//source voltage (in Volts) V=1351/sqrt(3);//in volts V_phase=0; Z=360+%i*150;//per-phase impedance(in ohms) I=V/Z;//current in the circuit (in Amperes) r=real(I); i=imag(I); I_mag=sqrt(r^2+i^2);//in ampere I_phase=atand(i/r);//degree //Refer to fig 1.19(a) V_ab=1351*(cosd(-30)+%i*sind(-30));//in Volts I_aA=2*(cosd(I_phase)+%i*sind(I_phase));//in Amperes V_cb=1351*(cosd(-90)+%i*sind(-90));//in Volts I_cC=2*(cosd(I_phase-120)+%i*sind(I_phase-120));//in Amperes P1=real(V_ab*conj(I_aA));//reading of wattmeter 1 (in Watts) disp(P1,'Reading of wattmeter W1 (in Watts) ='); P2=real(V_cb*conj(I_cC));//reading of wattmeter 2 (in Watts) disp(P2,'Reading of wattmeter W2 (in Watts)='); P=P1+P2;//total power developed (in Watts) disp(P,'Total power developed (in Watts)=' ); pf=cosd(I_phase);//power factor disp(pf,'power factor=')