// Calculating the amount of water required per second, area of water duct and pumping power clc; disp('Example 4.27, Page No. = 4.52') // Given Data Q = 800;// Stator copper losses (in kW) Ti = 38;// Temperature of water inlet (in degree celsius) To = 68;// Temperature of water outlet (in degree celsius) Ns = 48;// Number of slots v = 1;// velocity (in meter per second) p = 300*10^(3);// Pumping pressure (in N per meter square) n = 0.6;// Efficiency // Calculation of the volume of water required per second T = To-Ti;// Temperature rise of water (in degree celsius) Vwl = 0.24*Q/T;// Amount of water (in litre per second) Vwm = Vwl*10^(-3);// Amount of water (in meter cube per second) N_cond = 2*Ns;// Since each slot has two conductors Total number of stator conductors N_sub_cond = 32*N_cond;// Since each conductor is subdivided into 32 sub-conductors Vw_sub_cond = Vwl/N_sub_cond;// Volume of water required for each sub-conductors (in litre per second) disp(Vw_sub_cond,'Volume of water required for each sub-conductors (litre per second)='); A = Vw_sub_cond*10^(-3)/v;// Area of each duct (in meter square) A = A*10^(6);// Area of each duct (in mm square) disp(A,'Area of each duct (mm square)='); Q = 800-500;// Since it ia a 500 KW direct cooled turbo-alternator (in kW) P = (Q*10^(3)*Vwm/n)*10^(-3);// Pumping power (in kW) disp(P,'Pumping power (kW)='); //in book Vwl is equal to 0.00208 (litre per second), A is 2 (mm square) and pumping power is 3.2 (kW). The answers vary due to round off error