// Calculating the magnetizing current per phase clc; disp('Example 10.16, Page No. = 10.44') // Given Data // 3 phase delta connected induction motor P = 75;// Power rating (in kw) V = 400;// Voltage rating f = 50;// Frequency (in Hz) p = 6;// Number of poles D = 0.3;// Diameter of motor core (in meter) L = 0.12;// Length of motor core (in meter) Nss = 72;// Number of stator slots Nc = 20;// Number of conductors per slot lg = 0.55;// Length of air gap (in meter) Kg = 1.2// Gap constraction factor Coil_Span = 11;// Coil span (slots) // Calculation of the magnetizing current per phase q = Nss/(3*p);// Slots per pole per phase Kd = sin(60/2*%pi/180)/(q*sin(60/(2*4)*%pi/180));// Distribution factor Ns_pole = Nss/p;// Slots per pole alpha = 1/Ns_pole*180;// Angle of chording (in degree). Since the winding is chorded by 1 slot pitch Kp = cos(alpha/2*%pi/180);// Pitch factor Kws = Kd*Kp;// Stator winding factor Ns = Nss*Nc;// Total stator conductors Ts = Ns/(3*2);// Stator turns per phase Eb = V;// Stator voltage per phase. Since machine is delta connected Fm = Eb/(4.44*f*Ts*Kws);// Flux per pole (in Wb) A = %pi*D*L/p;// Area per pole (in meter square) Bav = Fm/A;// Average air gap density (in Wb per meter square) Bg60 = 1.36*Bav;// Gap flux density at 30 degree from pole axis ATg = 800000*Bg60*Kg*lg*10^(-3);// Mmf required for air gap (in A) ATi = 0.35*ATg;// Mmf for iron parts (in A). Since mmf required for iron parts is 35% of air gap mmf AT60 = ATg+ATi;// Total mmf (in A) Im = 0.427*p*AT60/(Kws*Ts);// Magnetizing current per phase (in ampere) disp(Im,'Magnetizing current per phase (Ampere) ='); //in book answer is 4.56 Ampere. The answers vary due to round off error