//Example_a_9_6 page no:406 clc; Vl=400; Vrnmag=400/sqrt(3); Vrnang=0; Vynmag=400/sqrt(3); Vrnang=-120; Vbnmag=400/sqrt(3); Vrnang=-240; R=10; omega=314; L=1; C=100*10^-6; Yph=(1/R)+(1/(%i*omega*L))+(%i*omega*C); Iph=Vrnmag*Yph;//multiplication of Vrnmag and Yph is rounded off in text book so output line current varies sligthly Iphmag=sqrt(real(Iph)^2+imag(Iph)^2); Iphang=atand(imag(Iph)/real(Iph)); P=sqrt(3)*Vl*Iphmag*cosd(Iphang); pf=cosd(Iphang); disp(Iphmag,"the magnitude of line current is (in A)"); disp(Iphang,"the angle of line current is (in degree)"); disp(P,"the power is (in W)"); disp(pf,"the power factor is"); //multiplication of Vrnmag and Yph is rounded off in text book so output line current varies sligthly //Iphmag and Iphang are rounded off in text book so calculated power varies with the textbook