// Example 11.1 // Computation of (a) The armature current when operating at rated conditions // (b) The resistance and power rating of an external resistance required in // series with the shunt field circuit to operate at 125 percent rated speed // Page No. 448 clc; clear; close; // Given data HP=40; // hp rating of the device Perratedload=0.902; // Percentage rated load VT=240; // Voltage value of motor RF=99.5; // Resistance of shunt motor Nf=1231; // Turns per pole of the shunt motor Ra=0.0680; // Armature resistance RIP=0.0198; // Interpole winding resistance Rs=0.00911; // Resistance of series field winding Bp1=0.70; // Flux density for a net mmf n1=1150; // Speed of shunt motor // (a) The armature current when operating at rated conditions P=HP*746/Perratedload; IT=P/VT; // Total current IF=VT/RF; // Field current Ia=IT-IF; // (b) The resistance and power rating of an external resistance required in // series with the shunt field circuit to operate at 125 percent rated speed Fnet=Nf*IF; // Corresponding mmf from magnetization curve Racir=Ra+RIP+Rs; n2=n1*1.25; // 125 percent rated speed // Shaft load is adjusted to value that limits the armature current to 115% // of rated current Bp2=Bp1*(n1/n2)*((VT-Ia*Racir*1.15)/(VT-Ia*Racir)) FF=2.3*1000; IF1=FF/Nf; Rx=(VT/IF1)-RF; PRx=(IF1^2)*Rx; // Display result on command window printf("\n The armature current = %0.2f A ",Ia); printf("\n The resistance rating = %0.1f Ohm ",Rx); printf("\n The power rating = %0.1f W ",PRx); //Note: Answer varies due to round-off errors