// Example 10.6 // Computation of Induced emf // Page No. 418 clc; clear; close; // Given data P=25000; // Power of the generator VT=250; // Rated voltade of the machine Ra=0.1053; // Armature resistance Rip=0.0306; // Resistance of interpolar winding Rcw=0.0141; // Resistance of compensating windings // Induced emf Ia=P/VT; // Armature current Racir=Ra+Rip+Rcw; // Resistance of armature circuit Ea=VT+Ia*Racir; // Induced emf // Display result on command window printf("\n Induced emf = %0.0f V ",Ea);