//Example 5_3_u2 clc(); clear; //To calculate the transition temprature and critical field hc1=1.4*10^5 //units in amp/meter hc2=4.2*10^5 //units in amp/meter t1=14 //units in K t2=13 //units in K tc=sqrt((hc1*t2^2-hc2*t1^2)/(hc1-hc2)) //units in K printf("Transition temprature is Tc=%.2f K",tc) hc1_ho=1-(t1/tc)^2 ho=hc1/hc1_ho //units in amp/meter printf("\nCritical field Ho=%.1f amp/meter",ho)