clc; clear all; I0 = 1e-12; // Standard intensity Watts per square meter\ //PART1 I1 = (10e-12)*(10^8)// Intensity of sound produced by the electric generator in Watts per square meter disp('W/m^2',I1,'Intensity of sound generated by electric motor is') b1 = 80;// Intensity level of sound produced by the electric generator in dB b2 = 70; // Intensity level of room I2 = 1e-5; // Intensity of sound of existing room Watts per square meter b = (10*log10((I1+I2)/I0))-10;; disp('dB',b,'The resultant intensity level of sound is ')