// Given:- P1 = 1.0 // pressure of industrial discharge in bar T1 = 478.0 // temperature of industrial discharge in kelvin m1dot = 69.78 // mass flow rate of industrial discharge in kg/s T2 = 400.0 // temperature of exit products from steam generator in kelvin P2 = 1.0 // pressure of exit products from steam generator in bar P3 = 0.275 // pressure of water stream entering the generator in Mpa T3 = 38.9 // temperature of water stream entering the generator in degree celcius m3dot = 2.079 // mass flow rate of water stream entering in kg/s P5 = 0.07 // exit pressure of the turbine in bars x5 = 0.93 // quality of turbine exit // Part (a) m2dot = m1dot // since gas and water streams do not mix m5dot = m3dot // --DO // from table A-22, A-2 and A-3:- h1 = 480.3 // in kj/kg h2 = 400.98 // in Kj/kg h3 = 162.9 // assumption: h3 = hf(T3), units in Kj/kg hf5 = 161.0 // in kj/kg hg5 = 2571.72 // in kj/kg // Part (b) P4 = P3 // from the assumption that there is no pressure drop for water flowing through the steam generator T4 = 180 // in degree celcius // Calculations:- h5 = hf5 + x5*(hg5-hf5) Wcvdot = m1dot*h1 + m3dot*h3 - m2dot*h2 - m5dot*h5 h4 = h3 + (m1dot/m3dot)*(h1 -h2) // from steady state energy rate balance // interpolating in table A-4, with these P4 and h4 // Results:- printf( ' The power developed by the turbine is %.2f kJ/s.',Wcvdot) printf( ' Turbine inlet temperature is %.2f degree celcius.',T4)